Click the version link below to download the firmware to your PC.
| Release Version | 01152026 Base3 Release 1.35 |
| Base3 Firmware Version | 1.35 |
Release Notes:
- BLE / RF pairing:
- Allow Legacy SET command to pair loco
- Only clear database record if paired BLE/RF loco exists when removing BLE/RF loco from system
- DATABASE:
- Add additional checks when setting Base Name via Cab2 to prevent database from being erased
- ID2 and ID4 SET Processing:
- Additional checks to prevent CAB2 data from showing “funky” characters when no data is received
- Internal Database Management:
- Add initialization for LC-Flags and BTMAC so that these fields are cleared when needed
- Corrections to Factory DIAGS:
- Needed changes to match the “Database”
- PDI Port Diagnostics:
- Added power checking and blink the LED above the port when power is overloaded or port is disabled based on if the ports are enabled/disabled via the GUI
- BCM database direct Read/Writes:
- Added the intercepts to make sure engines and trains are kept in sync when writes occur to the Speed, Train Builds, and 7 golden bytes, when modified. Affects ID2 only and is a critical fix supporting Cab3.
- Change PDI port controls:
- Allow for individual control of the PDI Ports and their respective enables. Enhance port assignment
ranges. Links to “diagnostics”
- Allow for individual control of the PDI Ports and their respective enables. Enhance port assignment
- Correct Wi-Fi Diagnostic monitoring as it failed to obtain a CID in all cases. Allows for complete
monitoring of Wi-Fi traffic by a debug utility to develop clients like Cab3. This change allows extensive
debugging support for code qualification - ID2:
- Allow synchronization of data writes to Speed, Train Assignments, and 7 golden bytes to not use
stale data from database. This only affects the GUI data “in-place” updates that occur without re-reading the record
- Allow synchronization of data writes to Speed, Train Assignments, and 7 golden bytes to not use
- Prevent random engine ID2 database record corruption when copying the head engine parameters
on a train build. This is a critical fix. - Remove unnecessary queue management on track signal to improve bandwidth for ID4 transmissions
- Improve recovery when client connections abort unexpectedly. Base3 will allow reconnect instead of flashing an error code or requiring a reboot to allow reconnection
- Support ID4 database management to allow updates of Train records when updating engine records
keeping the records in sync. Adds ALL database functionality to the ID4 database - Add “Reset” (numeric 0) commands to the Echo list for ID2 and ID4